Does the 2 Series MSO support filter math? Due to the limited display area on the 2 Series MSO's user interface, there is no filter button available for adding filter math waveforms. However, the 2 Series MSO supports filter files (.flt). To apply filter math, you will need to write the equation … FAQの該当製品: |
783038 |
Does the TBS1000C support serial bus decode? There is no built-in serial bus decode in the TBS1000C series. However, with the TekScope PC software, you can decode serial bus data traces captured from the TBS1000C. The TekScope Starter license includes I2C and RS232 serial bus decode, which can be … FAQの該当製品: |
783037 |
Is there an EDU version of TBS1000C available? We no longer offer a separate EDU version for the TBS1000C series. Instead, the educational features are standard on both the TBS1000C and TBS2000B. Educational features include: HelpEverywhere - on-screen tips that explain different instrument … FAQの該当製品: |
783036 |
Is there a rackmount kit for TBS1000C series? The rackmount kit RM2000B for the TBS1000C is obsoleted, and there is no replacement. We recommend using a generic 19-inch rack tray as an alterative. FAQの該当製品: |
783035 |
How to measure Temperature Coefficient of Resistance (TCR)? The Temperature Coefficient of Resistance, or TCR, is a measurement of a resistor's change in resistance per change in temperature. It is typically measured in ppm/°C, that is, parts-per-million change in ohms per change of 1 degree centigrade. Common … FAQの該当製品: |
783033 |
What is the bandwidth of Spectrum View on the MSO4/5/6? Spectrum View is a unique approach to frequency domain analysis present on some Tektronix oscilloscopes that allows you to simultaneously examine time and frequency aspects of a single signal. Learn more about Spectrum View here. The minimum bandwidth of … FAQの該当製品: |
783032 |
KickStart Battery Simulator App FAQs What benefits does the KickStart Software Battery Simulator App provide? The new Battery Simulator App includes: Ability to generate, edit, and simulate custom battery models using the 2380 E-load, 2281S Battery … FAQの該当製品: |
783031 |
What is the battery charging time for the 2 Series MSO? Charging with the instrument OFF One battery: ~3 hours Two batteries: ~5 hours Charging with the instrument ON One battery: ~6 hours Two batteries: ~10 hours Charging with the external battery charger TEKCHG-01, the charge time is 5 hours … FAQの該当製品: |
783023 |
Faq FAQの該当製品: |
783022 |
How do I create a single pulse with SourceXpress? Creating single pulses for your Arbitrary Waveform Generator in SourceXpress simply requires some consideration to your AWG’s sample rate, and a waveform file. Remember the time of any signal output by an AWG = the sample rate of the AWG / the number of … FAQの該当製品: |
783021 |