Product Support and Downloads
While we’re happy to “talk tech” with you all day long, we know you’re in a hurry.
So we’ve made it easy for you to download product Manuals, Datasheets and Downloadable Software which includes Firmware, Drivers, etc. for all our current products, and many discontinued products as well. Just tell us which product you’re using, and we’ll provide you with list of latest documents and resources that you can download.
The product model you have chosen is currently available for purchase. The following support information is available.
-
Datasheet Literature Number: ReleaseDate KickStart Instrument Control Software Datasheet
KickStart Software simplifies what you need to know about your instrument so that in just minutes you can take the instrument out of the box and get real data on your device. KickStart Software enables quick test setup and data visualization when …1KW-60965-13 Mixed Domain Oscilloscopes
48W-60277-11 MDO4000 Series Mixed Domain Oscilloscopes (Replaced by MDO4000B)
Replaced by the MDO4000B -- Introducing the world’s first and only oscilloscope with a built-in spectrum analyzer. For the first time ever, you can capture time-correlated analog, digital, and RF signals for a complete system view of your device. See …48W-26875-4
-
Manuals Manual Type Part Number: ReleaseDate MDO4000C Series Mixed Domain Oscilloscopes Service Manual
Mixed Domain Oscilloscopes Service ManualService Manuals 077117902 MDO4000C Series Specifications and Performance Verification Manual
Mixed Domain OscilloscopePerformance Verification 077117801 MDO4000C, MDO4000B, MDO4000, MSO4000B, DPO4000B, and MDO3000 Series Programmer Manual
Digital oscilloscopes programming commandsProgrammer Manuals 077051009 MDO4000C Series User Manual
OscilloscopePrimary User 077116702 MDO4000C Series Oscilloscope Declassification and Security Instructions
Security and DeclassificationDeclassification Manuals 077118000
-
Technical Documents Document Type ReleaseDate Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope
THIS APPLICATION NOTE Explains the basic setup of a mixed signal oscilloscope (MSO) Tells how to interpret the logic signal display on a Tektronix MSO Explains how to easily identify and measure setup and hold …Application Note Capacitance and Inductance Measurements Using an Oscilloscope and a Function Generator
Most labs have an ample supply of digital multimeters (DMMs) for measuring DC resistance, but when it comes to measuring inductance, capacitance and impedance, it is not always easy to find an LCR meter. LCR meters operate by …Application Note When to Choose a Dedicated Arbitrary Function Generator (AFG)
This technical brief is written to help you determine the optimum method of arbitrary function generation for your needs. It shows examples of real-world applications and highlights key specifications of Tektronix and Keithley dedicated arbitrary …Technical Brief Tektronix Probe Selection Guide
Oscilloscope Probes Compatibility *1 Some probes require an external power supply (1103) when used with the TDS3000 series. *2 When using with MSO / DPO2000 series, a dedicated AC adapter (119-8726-00) and a power cable (161-0342-00) are …Product Selector Guide Advanced Radar Analysis: Tools for Measuring Modern Radar Application Note
Introduction In designing modern electronic warfare and radar systems, you face significant challenges. You must develop solutions with the flexibility and adaptability required for next-generation threat detection and avoidance. To succeed, you …Application Note Working Remotely with Tektronix Oscilloscopes
There are several approaches you can take to work remotely with Tektronix oscilloscopes. The available techniques differ somewhat between instruments that run the Windows operating system and instruments that do not. This guide is designed to help …Technical Brief Serial Support Using Tektronix Oscilloscopes and Optional Software
Tektronix oscilloscopes offer a portfolio of optional analysis capabilities to simplify serial bus debug or compliance verification. This selection matrix shows which serial standards are supported by each of the oscilloscope series.Product Selector Guide MDO4000 Series vs. Regular Oscilloscope FFTs
Examine the MDO4000 Series vs a regular oscilloscope FFTs.Competitive 4 Series MSO vs MDO4000C
COMPARISON FACT SHEET Screen Size and Waveform Viewing Area 4 Series MSO MDO4000C …Fact Sheet How to Minimize Probe Loading with Low Capacitance Probes
Probing a circuit always has some impact on signals. Probe loading changes the signal being probed and can cause measurement problems or can even cause a circuit to perform differently. Reducing capacitive loading can help minimize these effects. In …Application Note Practical EMI Troubleshooting
Introduction EMI/EMC regulations are in place throughout the world to provide a level of protection and safety for users of electrical and electronic equipment. A great deal of time and effort goes into the design of today’s products to …Application Note Debugging Serial Buses in Embedded System Designs
Introduction Embedded systems are literally everywhere in our society today. A simple definition of an embedded system is a specialpurpose computer system that is part of a larger system or machine with the intended purpose of …Application Note How to Use a Mixed Signal Oscilloscope to Test Digital Circuits
The ability to present both analog and digital representations of signals make mixed signal oscilloscopes (MSOs) ideal for verifying and debugging digital circuits. This application note provides tips to help you efficiently debug …Application Note Wave Inspector® Navigation and Search: Simplifying Waveform Analysis
Modern digital oscilloscopes can capture massive amounts of data which must then be analyzed. Discover how the Tektronix Wave Inspector® navigation and search capability gives you the tools to extract the answers you need fast and efficiently.Application Note Accurate Measurements Matter
MDO4000C Series measurements are taken on actual acquisition data - providing as much data to the measurement algorithms as possible. The Keysight 4000 X-Series uses the lower resolution display data, which can produce measurements that are …Fact Sheet SOLUTIONS FOR SCIENTIFIC AND ENGINEERING RESEARCH
Brochure Wi-Fi: Overview of the 802.11 Physical Layer and Transmitter Measurements
Introduction Wi-Fi is a technology that allows many electronic devices to exchange data or connect to the internet wirelessly using radio waves. The Wi-Fi Alliance defines Wi-Fi devices as any "Wireless Local Area Network (WLAN) …Primer Fundamentals of the MDO4000 Series Mixed Domain Oscilloscope
Chapter 1: Introduction The MDO4000 Series from Tektronix represents a new paradigm in instrumentation; the Mixed Domain Oscilloscope, or MDO. These are the first instruments that are designed specifically to make synchronized or time-correlated …Application Note MDO How it Works
In new designs, the level of integration among processors, sensors, and communications has increased, blurring the traditional lines between analog, digital, RF and power system design. Wireless technology is transforming the way engineers need to …Technical Brief Keysight N9000A CXA Spectrum Analyers vs MDO4000C Series Comparison
Side-by-side comparison on important specifications and features like correlating RF to other system signals and exceptionally wide capture bandwidth.Competitive MDO4000C Series vs. Rohde & Schwarz FSC Spectrum Analyzer Comparison
This fact sheet compares specifations and features of the MDO4000 Series to the Rohde & Schwarz FSC Spectrum AnalyzerCompetitive MDO4000C Series vs. Rohde & Schwarz FSL Spectrum Analyzer Comparison
MDO4000C Capabilities Not Available on Keysight N9322C 4 analog channels and 16 digital channels Function generator and DVM Serial / Parallel bus decode Capture bandwidth wide enough for …Competitive Keysight N9320B Spectrum Analyzer vs MDO4000C Comparison
MDO4000C Capabilities Not Available on Keysight N9320B 4 analog channels and 16 digital channels Function generator and DVM Serial / Parallel bus decode Capture bandwidth wide enough for …Competitive Keysight N9322C Spectrum Analyzer vs MDO4000C Series Comparison
MDO4000C Capabilities Not Available on Keysight N9322C 4 analog channels and 16 digital channels Function generator and DVM Serial / Parallel bus decode Capture bandwidth wide enough for …Competitive MDO4000C Series vs. Rohde & Schwarz FSV Spectrum Analyzer Comparison
This fact sheet compares the specifications and features of the MDO4000 Series to the Rohde & Schwarz FSV Spectrum AnalyzerCompetitive Measuring Wireless Power Charging Systems for Portable Electronics
Introduction Mobile electronics can be found everywhere - homes, hospitals, schools, purses, and pockets. With the explosion in portability, consumers have come to expect and demand long battery life. Energy efficient design …Application Note Keysight 4000X vs MDO4000C Competitive Comparison
Side-by-side comparison on important features like serial triggering and decode, waveform navigation and search, waveform capture rate, digital debug with MSO, and more.Competitive MDO4000C and MDO3000 Series Comparison Fact Sheet
This fact sheet compares features and specifications of MDO4000C and MDO3000 Series mixed domain oscillscopes.Product Selector Guide Secrets of MDO Performance
Learn how:The MDO4000 Series are able to leverage oscilloscope acquisition technology to achieve spectral fidelity on par with entry level spectrum analyzers.The design techniques used in the MDO4000 Series allow them to achieve spectral fidelity far …Whitepaper Power Supply Measurement and Analysis Primer
A power supply is a component, subsystem, or system that converts electrical power from one form to another; commonly from alternating current (AC) utility power to direct current (DC) power. The proper operation of electronic devices ranging from …Primer Power Supply Measurement & Analysis with Bench Oscilloscopes
Introduction Power supplies can be found in many different electronic devices, from children’s toys to computers and office equipment to industrial equipment. They are used to convert electrical power from one form to another for …Application Note Introduction to Video Measurements
In this application note, we demonstrate using a MSO/DPO5000, MDO/MSO/DPO4000 and MDO/MSO/DPO3000 Series Oscilloscope to make a variety of video measurements that are common in standard and high definition systems.Application Note Tektronix MDO4000C Series Oscilloscopes
This demonstration guide takes you through a series of step-by-step demonstrations on how the MDO4000C Series oscilloscope helps simplify the debug of mixed signal designs with its powerful functionality and integrated test instruments. This …How-to Guide Testing a New Switch Mode Power Supply Design Poster
Get a quick overview of the key measurements for verifying a new switch mode power supply (SMPS) design. This poster shows key measurements, from verifying your prototype during initial startup, to optimizing switching loss and magnetic losses, to …Poster Replicating Real World Signals with an Arbitrary/Function Generator
Learn how to simulate sensor and bus signals on an arbitrary waveform generator. Find out how to capture signals using an oscilloscope, edit them using PC software, and play them back on an arbitrary/function generator.Application Note MDO Signal Path Teardown Poster
MDO4000 and MDO3000 Mixed Domain Oscilloscopes deliver uncompromised oscilloscope performance combined with spectrum analyzer performance on par with standalone spectrum analyzers. But how do they do it? The answer lies in Tektronix’ custom ASICs, a …Poster
-
Software Document Type Part Number: ReleaseDate KickStart Instrument Control Software version 2.11.1
KickStart Software for the PC enables quick test setup and data visualization when using one or more instruments. Key Features • Save time by automating data collection of millions of readings. • Set up a multi-instrument test with the ability to …Application KICKSTART-2.11.1 KickStart Instrument Control Software version 2.11.0
KickStart Software for the PC enables quick test setup and data visualization when using one or more instruments. Key Features • Save time by automating data collection of millions of readings. • Set up a multi-instrument test with the ability to …Application KICKSTART-2.11.0 Tektronix Openchoice Desktop Application TDSPCS1 - V2.8
The Tektronix OpenChoice Desktop free application lets you capture oscilloscope screen images, waveform data, and settings from a Microsoft Windows computer. After installing the software, refer to the section “Connecting to a PC” in your …Utility 066093915 ARBEXPRESS WAVEFORM CREATION AND EDITING SW, V3.6
ArbExpress is a waveform creation and editing tool for Tektronix AWG and AFG instruments. It provides an easy to use and efficient way to create and edit waveforms, transfer waveforms to and from Arbitrary Waveform Generators (AWG), and …Application 066146106 ARBEXPRESS WAVEFORM CREATION AND EDITING SW, V3.5
ArbExpress is a waveform creation and editing tool for Tektronix AWG and AFG instruments. It provides an easy to use and efficient way to create and edit waveforms, transfer waveforms to and from Arbitrary Waveform Generators (AWG), and …Application 066146105 TEKVISA Connectivity Software - V4.2.0
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093812 DPO2000, MSO2000, DPO3000 and DPO4000, MSO3000 and MSO4000, MDO3000 and MDO4000 and MDO3 IVI Driver - V1.5
The Tektronix MSO/DPO2000, MDO/MSO/DPO3000, MDO/MSO/DPO4000 and MDO3 IVI Driver is an IVI class-compliant driver. It complies with Scope Class specifications (IVI-4.1) as defined by the IVI foundation. An IVI class-compliant specific driver for an …Driver 066133104 MDO4000C FIRMWARE RELEASE - v1.10
MDO4000C firmware updateFirmware 066179905 TEKVISA CONNECTIVITY SOFTWARE - V4.1.1
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …Driver 066093811 MDO4000C FIRMWARE V1.04
This firmware is for all MDO4000C Series oscilloscopes.Firmware 066179902 Tektronix Openchoice Desktop Application TDSPCS1 - v2.6
The Tektronix OpenChoice Desktop free application lets you capture oscilloscope screen images, waveform data, and settings from a Microsoft Windows computer. After installing the software, refer to the section “Connecting to a PC” in your …Utility 066093914 ARBEXPRESS WAVEFORM CREATION AND EDITING SW, V3.4
ArbExpress is a waveform creation and editing tool for Tektronix AWG and AFG instruments. It provides an easy to use and efficient way to create and edit waveforms, transfer waveforms to and from Arbitrary Waveform Generators (AWG), and …Application 066146104
-
FAQS FAQ ID How do I clear my memory using TekSecure on a MSO/DPO/MDO4000 Series oscilloscope?
This procedure for clearing the memory on oscilloscope can be applied to the DPO/MSO/MDO4000, DPO/MSO3000 and DPO/MSO2000 Series oscilloscope families. By clearing the memory you will lose all saved reference waveforms, saved setups and all other …64686 How do I mount a network drive on my MDO3000 or MDO4000C oscilloscope?
This procedure also applies to the DPO/MSO/MDO4000/4000B series oscilloscopes. Note: This Mount a network drive will not work with a direct (peer-to-peer) connection. Must go through your local DNS server. To begin, press the “Menu” button in the …66201 How do I reduce noise on signals using an oscilloscope?
There are many methods to reduce many types of noise on a signal. Tektronix oscilloscopes can do this through bandwidth limiting the scope input, averaging your signal, changing the sampling method to hi-resolution mode, and more. This video …64706 How do I run a Signal Path Compensation (SPC) on an DPO/MSO/MDO4000 Series oscilloscope?
Signal Path Compensation (SPC) should be run anytime you are getting DC offsets in your signals, or your scope has moved locations and might have changed temperature, or if it's been more then a month since your last SPC. This is a standard procedure …64681 How do I set up a CAN bus decode?
Depending on the scope you have, the available options for decoding your CAN signal will depend on the compatibility. For all the DPO/MSO2000/3000/4000/5000 and MDO3000/4000 Series scopes, there are modules or license keys specifically designed for …64751 I recently registered our Tektronix oscilloscope, updated the firmware and am currently trying to activate the free DVM & Frequency Counter. I don’t see any software downloads for activating the DVM. Am I doing something wrong, or looking in the wrong spot?
After you have registered your oscilloscope on Tek.com, you should have received an email with instructions. The email is sent to the address you used to login to tek.com. If you haven't received the email after registration: Check your spam …468046 How do I Set Up a LIN serial Bus decode?
For doing Local Interconnect Network (LIN) bus decode Tektronix recommends using a DPO/MSO/MDO series oscilloscope. This feature can be purchased as a module or option key on any of these types of oscilloscopes. Start by turning it on the bus channel …64781 How do I configure the LAN settings on an MDO4000C series oscilloscope?
This procedure also applies to the DPO/MSO/MDO4000B series oscilloscopes. As it stands now, all 4000 series scopes require a live network connection be made on the scope in order to set and save LAN settings. If the scope does not have a network …66236 How do I utilize the measurement features on a DPO/MSO/MDO3000 and DPO/MSO/MDO4000 Series oscilloscope?
The Measurements are the same as the DPO/MSO2000 Series scopes. By going into the measurement menu you can add and remove up to 4 measurements. You can gate the measurements which allows you to only measure the part of the captured waveform that you …64651 How do I set up a I2C Bus Decode?
The procedure to set up a I2C bus decode and trigger is simple once you understand the basics. First you have to have the correct module or scope option. Second make sure your signal is on screen and taking up as much of the DAC as possible with good …64756 How do I utilize the math channel feature on a DPO/MSO/MDO3000 or DPO/MSO/MDO4000 Series oscilloscope?
There are three main functionalities on the Math button on this scope. They range from Dual Waveform Math, FFT (Fast Fourier Transform), and Advance Math. These three functionalities have a range of abilities and are explained in this short YouTube …64656 How do I erase and declassify an MSO/DPO2000, MSO/DPO/MDO3000, and MSO/DPO/MDO4000 Series oscilloscope?
This example will show you how to declassify the MDO4000/B/C Series oscilloscope. This procedure also applies to the MSO/DPO4000/B, MSO/DPO/MDO3000, and the MSO/DPO2000/B series of oscilloscope.The first step in the declassification process is …66231 Is there a mictor adapter for the P6616 (logic probe for MSO5000B, MSO4000B, and MDO4000C + MDO4MSO) or P6516 (logic probe for the MSO4000 Series) or the P6316 (logic probe for MSO2000, MSO3000, MDO3000 + MDO3MSO Series)?
A mictor adapter is available from our partner Nexus Technologies. Use the mictor adapter NEX-HD2HEADER http://www.nexustechnology.com/products/laAccessories/hd2header/59716 What is the maximum bit rate a decoded SPI bus can trigger on?
Different oscilloscopes have different triggering circuitry therefor the limits of what speeds can be achieved vary by scope. Please use the following table to easily look up your scope and determine your max SPI bus trigger level. For more …62256 What cart does my scope use?
Below are the Instrument Carts that can be purchased from Tektronix. K4000 K420 K475 More information can …64561 Why does the Tkdpo2k3k4k_ReadWaveform() function in the Tkdpo2k3k4k IVI-C driver time out every time I call it when I am connected to the instrument via Ethernet? The function call works fine over USB, but over Ethernet it always times out.
The Tkdpo2k3k4k_ReadWaveform() function makes use of the Service Request Event in VISA so the scope can notify the driver when it has completed its acquisition and the waveform data is ready to be fetched as opposed to the driver polling the scope …72221 How do I set up a RS232 bus decode?
The procedure to set up a RS232 bus decode and trigger is simple once you understand the basics. First you need to have the correct module or scope option. Second make sure your signal is on screen and taking up as much of the screen as possible with …64761 How do I set up an Ethernet bus decode?
Make sure your setup is prepared to decode, that you have the needed probes, scope options, test boards, etc. Once you have the options it's important to know how to use the options and probe your signal. To setup Ethernet bus decoding, turn on your …64731 How do I save and load a reference waveform to a DPO/MSO3000 series oscilloscope?
This Video will explain how to setup, save and load a reference waveform. It can be done through a USB flash drive or by internal memory. This method for using reference waveforms can be applied to all MSO/DPO2000, MSO/DPO3000, MSO/DPO/MDO4000 …64641 How do I Set up a Military Standard 1553 serial bus decode?
For doing Military Standard 1553 bus decode Tektronix recommends using a DPO/MSO/MDO 2000 or higher series oscilloscope. This feature can be purchased as a module or option key on any of these types of oscilloscopes. Start by turning it on the bus …64776 How can I increase the measurement accuracy using automated measurements vs cursors?
While Cursors are quick and easy at approximating measurements, using the automated measurements can give you a much better and accurate measurement results. Here are some techniques to be successful in making accurate measurements. Always use …62606 How Do I Set Up a Parallel Bus Decode?
For doing Parallel Bus decode Tektronix recommends using a MSO or MDO + MSO option Series oscilloscopes. This feature comes standard in the Bus menu and can be used in a variety of ways. Start by turning it on, selecting the channel and setting your …64771 How do I connect an SMA male output to Oscilloscopes with TekVPI BNC inputs?
Use a Tektronix part number 015-0572-XX SMA female to BNC male adapter. This adapter will plug onto the BNC on the front of the scope and connect to a SMA cable. For more questions please press the "Contact Us" button on the right of the screen.63516 How do I set up a USB bus decode?
First you must have the USB module or option key that enables USB decoding for your scope as well as proper probes. For help finding the right probe use our probe selector tool. When you go into the bus option you must select USB and then make sure …64726 What probe interface does my oscilloscope have?
Oscilloscope series Probe interface CSA7000/CSA7000B TekConnect DPO2000 TekVPI DPO3000 …64251 What's included in the MDO3000 and MDO4000C DDU option?
The Distribution Demo Unit (DDU) option on Tektronix oscilloscopes is an option provided to distributors for demoing scopes to customers with a set time limit before it expires. Questions arise about what's included in the MDO3000 and MDO4000C Series …72196 Why does my MDO4000C Series scope cause my USB flash drive to pop up with a scan and fix message on my PC?
The MDO4000C products have a new Linux kernel. The security settings of this kernel require that any USB flash drive that is removed without unmounting get tagged as a suspicious device. This can be seen when a drive is written to on the scope …72166 Programing - How to get and plot a waveform from DPO/MSO/MDO4000 Series scope in Python
There are a few things that are needed for programming with an oscilloscope. First it's important to have a copy of your oscilloscopes Programmers manual. This can be found be searching for manuals on Tek.com and specifying Programmers manual in the …64796 Will the P6516 Logic Probe work on my MSO4000B, MDO4000B and MDO4000C Series oscilloscopes?
The P6516 logic probe was only used with the original MSO4000 series. For the subsequent MSO4000B, MDO4000B and MDO4000C Series oscilloscopes, the P6516 was replaced by the P6616 logic probe. The P6616 logic probe will not work on the original …246206 Do the existing MSO/DPO/MDO4000/B Series application modules work with the MDO4000C?
Yes, almost all work from all legacy MSO/DPO/MDO4000/B series scopes. The only one that has some requirements is the MDO4TRIG which requires a spectrum analyzer option MDO4SA3 or MDO4SA6 be installed on your MDO4000C before RF triggering capabilities …72146 Does Tektronix have a 12-bit oscilloscope?
Yes! Tektronix offers many different models of real-time oscilloscopes that provide 12-bit or greater vertical resolution for a variety of applications. Because many high-vertical-resolution oscilloscopes on the market have technical trade-offs such …69266 Do we get a Spectrum Analyzer equal to the analog bandwidth with a purchase of the MDO4000C?
No, all MDO4000C come without Spectrum Analyzer (SA) options. For flexibility you can now order the base unit and add either option MDO4SA3 (3GHz RF channel) or MDO4SA6 (6GHz RF channel). When MDO4SA3 or MDO4SA6 is NOT ordered, the oscilloscope comes …72131 How do I utilize the XY display feature on a DPO/MSO/MDO4000 Series oscilloscope?
The XY display format can be used to measure the phase relationship between two or more synchronous signals. This measurement technique involves inputting one signal into the vertical system as usual and then another signal into the horizontal system …64666 How can I change the TekVISA Instrument descriptor “device name” used to identify the oscilloscopes to which I routinely connect?
Open TekVISA V4.0.0+ OpenChoice Instrument Manager by selecting Start -> All Programs -> TekVISA -> OpenChoice Instrument Manager.Select (highlight) the Instrument descriptor listed in the Instruments list for the connected Oscilloscope.Click the …66181 I downloaded and Installed OpenChoice Desktop, but it doesn't recognize my scope.
Refer to the Prerequisites.txt file available to download on the same page for OpenChoice desktop. Make sure you have all the prerequisites specified. Prerequisites 1. PC equipped with Microsoft Windows 7 32 Bit and 64 Bit OS, Windows 8.1 32 Bit …474266 I could not find any information regarding the increase in bits in resolution for HiRes mode. Is there any information available?
The increase in bits in resolution depends on the decimation ratio. The decimation ratio can be determined as follows:D = MFs / FsMFs is the maximum non-interleaved sampling frequency of the scope. For example: 5 GS/s for the DPO4104B or 2.5 GS/s …55421 I cannot see my signal on the Oscilloscope. What can I do?
You have many options to help diagnose this issue, below are a few suggestions to get started. If you find yourself needing more help, please connect with our Technical Support Center. You can get started by pressing the "Contact Us" button on the …63686 When customer upgrades bandwidth on a MDO4000C, will the warranty be 3 years from the date of bandwidth upgrade?
No, the warranty does not get reset with the purchase of a bandwidth upgrade or spectrum analyzer upgrade. However, the instrument is returned from the Tektronix Service Center fully calibrated. If you have further questions please connect with our …72156 When analog bandwidth is upgraded on a MDO4000C do we get new probes?
MDO4000C scopes with or less than 500MHz analog bandwidth come standard with TPP0500B 500MHz passive probes, one per channel. If upgrade to 1GHz analog bandwidth you will receive TPP1000 1GHz passive probes that come with the upgrade.72126 Which probes are compatible with oscilloscopes with the TekVPI probe interface?
There are a couple different types of TekVPI interfaces, one with a notch and one without. The notch was implemented later and was put in place because the front end was designed differently and communicates uniquely with those types of probes …56226 Why isn’t the TPP1000 (Tektronix Passive Probe 1GHz) compatible with my scope?
Short answer is that if your scope doesn’t have the notched key that allows the probe to connect, then the TPP probe requires a different termination resistance than what your scope can provide. Long answer is that traditionally, passive probes …467701 What MDO4000C options can be upgraded in the field?
Only MSO, AFG & DVM/Frequency counter can be upgraded in the field. The DVM/Frequency counter is available on all models and is free when when the product is registered. Analog bandwidth upgrade options require the instrument to be calibrated at the …72136 What probes are supported on the RF input of the MDO3000 and MDO4000 series?
The RF input on the MDO3000 and MDO4000 series has an N connector, so the RF input can support cables, antennas, and other adapters typically used with a spectrum analyzer. The RF input is 50 ohms and it is AC coupled. Below is a listing of some …64506 What is the standard warranty on the MDO4000C?
The MDO4000C comes standard with a 3 year product warranty on the instrument and a 1 year warranty on the probes. Note: The MDO4000C is the first product to offer a new service option called the Total Protection Plan with options for 3 or 5 years …72151 What are the acquisition bands in the MDO4000, MDO4000B, and MDO4000C?
The acquisition bands are as follows: 1) 9kHz - 3.75 GHz (MDO4000B/C) or 50 kHz - 3.75 GHz (MDO4000)2) 2.75 GHz - 4.5 GHz3) 3.5 GHz - 6.0 GHzThese three bands overlap, allowing the MDO to have a 1 GHz capture bandwidth at all center frequencies and …69341 What is aliasing?
Aliasing occurs when an oscilloscope does not sample the signal fast enough to construct an accurate waveform record. The signal frequency is misidentified, and the waveforms displayed on an oscilloscope become indistinguishable. Aliasing is …64691 What are the primary differences between the DPO/MSO4000B, MDO4000, MDO4000B, and MDO4000C?
The 4000 Series Mixed Domain Oscilloscopes (MDO) continues to be the only true RF/Time domain syncronized instrument on the market. The major differences between revisions of the DPO/MSO/MDO4000 Series are described below. Please note the MDO4000C …72111 When should I use MagniVu on my oscilloscope?
MagniVu allows you to have higher resolution to accurately determine edge placement on your digital data. It helps you to make precise timing measurements on digital edges. On the MSO/MDO4000/B/C and MSO5000/B Series, you can see up to 32 times more …63886 What is enhanced security option MDO4SEC on the MDO4000C?
Option MDO4SEC add’s enhanced instrument security to enable password protected control of turning on/off all instrument ports and instrument firmware update functionality. It is a one-time permanent upgrade.72141 What feature does the DPO4BND included?
DPO4BND includes the features for the following modules …72101 What are some of the benefits of the TekVPI probe interface?
The biggest benefits of the TekVPI™ probe interface are versatility and ease of use. Oscilloscopes with TekVPI interface support a wide range of probes including TekVPI probes, BNC and TekProbe-BNC Level 1 probes, and TekProbe-BNC Level 2 probes …56016 Why Should My Signal Fit Within The Screen Of My Tektronix Oscilloscope?
Scaling your signal to fit within the screen will remove signal distortion caused by clipping. Clipping is caused by exceeding the limits of the instrument's input. Tektronix's digital oscilloscopes are designed such that each division is 25 digital …60306 Why do I see 16 flat lines for the MSO digital logic inputs when the same signals are displayed properly on the analog channels and all channels are setup for valid trigger threshold levels?
A common mistake for some, we first recommend verifing that the front panel MSO digital probe is properly connected by squeezing the probe's side latch buttons to un-plug, remove the probe then re-insert the probe label side up into the front panel …60251 The data sheet for my oscilloscope says that the vertical input sensitivity is 1 mV/div to 10 V/div in 1 MΩ mode. But I turn the Vertical Scale control fully clockwise and I can only get down to 10 mV/div. What am I doing wrong?
You probably aren't doing anything wrong. But you do have a 10X probe attached to that channel, right? The 1 mV/div specs relate to the oscilloscope inputs. If the signal’s source impedance is relatively low (<< 1 MOhm), the signal’s frequency is …58571 Programing - How do I get a Screen Capture from DPO4000 scope using Python?
There are a few things that are needed for programming with an oscilloscope. First it's important to have a copy of your oscilloscopes Programmers manual. This can be found be searching for manuals on Tek.com and specifying Programmers manual in the …64791 Companies such as National Instruments and LeCroy sell USB-to-GPIB adapters. How do their adapters compare to the TEK-USB-488?
The products from National Instruments (GPIB-USB-B or GPIB-USB-HS) and LeCroy (WS-GPIB) are USB host to GPIB device adapter. These would be used for instruments that have a GPIB interface with controllers that have a USB port. The TEK-USB-488 was …56456 Can my oscilloscope operate on 400Hz power?
Most scopes have a wide range of operating voltages and frequencies, a full list can be found in the user manual of your specific oscilloscope. If you're having trouble finding your answer or can't find the manual, please call our Technical Support …63266 My company purchased a Tektronix MDO4104C oscilloscope last year and we purchased three application modules. They are not showing up on our scope anymore and we would like some help getting them back.
Push Utility on the front panel. If needed, push Utility Page on the lower menu and turn multipurpose knob a to select Config. Push Manage Modules and Options on the lower menu, and then push License Type on the side menu until “Modules” is selected …468031 Is Analog BW upgradable on the MDO4000C and can it be upgraded in the field?
Yes, the MDO4000C analog bandwidth has upgradable bandwidth options. Once purchased it does require a new calibration at Tektronix Service Center.72121 Can active probes with TekProbe interface (such as a P6205) be used on the DPO4000B or MSO4000B series scopes?
Yes. A TPA-BNC adaptor is required for people to connect legacy TekProbe interface probes to the new TekVPI interface. The adapter works on any TekVPI scopes inlcuding the MSO/DPO/MDO4000/B/C, MSO/DPO/MDO3000 MSO/DPO2000/B or MSO/DPO5000/B or …60416 Can the MDO3000 capture the time domain and the frequency domain simultaneously?
The MDO3000 is most importantly an oscilloscope, but has a total of 6 different instruments individually built into it. Designed in such a way to minimize the clutter on your bench but give you the power and versatility you need. Unfortunately to be …69306 : Can the optional AFG in the MDO3000, MDO4000C and 5 Series MSO be set to sweep?
AFG in MDO3000, MDO4000C, and 5 Series MSO do not have sweep function. But a limited sweep may be created using the arbitrary function. Example: Create a sweep from 100 KHz to 250 KHz. ArbExpress (free software on Tek.com) select Equation Editor …474056 Can the P6316, P6516, or P6616 logic probes be used interchangeably?
The simple answer is no they can't be used interchangeably. The front end of the logic channels are different so different logic probes are needed between the scopes. For MSO2000/B, MSO3000, MDO3000, 3 Series MDO, and 2 Series MSO oscilloscopes …59166