Contact us
Call
Call us at
Available 6:00 AM – 5:00 PM (PST) Business Days
Download
Download Manuals, Datasheets, Software and more:
Feedback
Product Support and Downloads
While we’re happy to “talk tech” with you all day long, we know you’re in a hurry.
So we’ve made it easy for you to download product Manuals, Datasheets and Downloadable Software which includes Firmware, Drivers, etc. for all our current products, and many discontinued products as well. Just tell us which product you’re using, and we’ll provide you with list of latest documents and resources that you can download.
The product model you have chosen is currently available for purchase. The following support information is available.
-
Datasheet Literature Number: ReleaseDate Passive High Voltage Probes
The Passive High Voltage Probes (P5100A, TPP0850, P5122, P5150, P6015A) datasheet provides an overview of the product's features, important specifications, and ordering information.56W-10262-15
-
Manuals Manual Type Part Number: ReleaseDate TPH1000 Probe Holder Instructions
Probe HolderUser Manuals 071289401 Probes and Accessories Declassification and Security Instructions
Declassification and SecurityDeclassification Manuals 071238400 Tektronix Supplemental, 071296605
Product Information Sheet for People‚s Republic of ChinaUser Manuals 071296605 Tektronix Supplemental, 071329304
Product Information Sheet for People‚s Republic of ChinaUser Manuals 071329304 Tektronix Supplemental, 071329404
Product Information Sheet for People‚s Republic of ChinaUser Manuals 071329404 P5122
200 MHz 100X High Voltage Probe InstructionsUser Manuals 071272003 P5100A
500 MHz 100X High Voltage Probe InstructionsPrimary User 071288203 P5100A & P5150
500 MHz High Voltage Probes Technical ReferenceService Manuals 077053002 P5150
500 MHz 50X High Voltage Probe InstructionsPrimary User 071288501 TPP0850 Probe
Describes the use of the probe and accessories InstructionsUser Manuals 071288400 P5100A
Describes the use of the probe and accessories InstructionsUser Manuals 071288200 Voltage Probe Standard Compliance Update
The following probes do not comply with changes resulting from Amendment 1 (2008) to the IEC / EN 61010-031:2002 Standard and are not intended to be sold or placed on the market in the European Union after March 1, 2011. Read This FirstUser Manuals 061436800 P5122
200 MHz 100X High Voltage Probe InstructionsPrimary User 071272001 Probe Safety Information
Prevent unsafe practices - always use these probes with ground-referenced oscilloscopes. Read This FirstUser Manuals 071268200 P6015A
1000X High Voltage Probe Instruction ManualPrimary User 070822305 P5120 200 MHz Passive High-Voltage Probe
200 MHz Passive High-Voltage Probe InstructionsPrimary User 071146300
-
Technical Documents Document Type ReleaseDate Testing High Power Semiconductor Devices from Inception to Market
Introduction This primer examines the life cycle of a power semiconductor device and the tremendous variety of test and characterization activities and measurement challenges faced by the engineers involved in each stage …Primer ABCs of Probes Primer
Precision Measurements Start at the Probe Tip Probes are vital to oscilloscope measurements. To understand how vital, disconnect the probes from an oscilloscope and try to make a measurement. It can’t be done. There has to be some kind of …Whitepaper Every oscilloscope needs a probe poster
Every oscilloscope needs a probe. To help you choose the right oscilloscope probe for your measurement need this poster provides an overview of probe types, important probing guidance, and key concepts.Poster Tektronix Probe Selection Guide
Oscilloscope Probes Compatibility *1 Some probes require an external power supply (1103) when used with the TDS3000 series. *2 When using with MSO / DPO2000 series, a dedicated AC adapter (119-8726-00) and a power cable (161-0342-00) are …Product Selector Guide
-
FAQS FAQ ID I have the P6015A probe without option 1R+ Probe Readout. Now I have a scope that will apply the 1000X attenuation factor automatically if the probe had that feature. Can it be added?
Yes, the BNC connector on the probe compensation box can be unsoldered, unscrewed, and replaced with the Tektronix part number 131-5320-00. All probe coding logic is contained in the new connector.61886 The data sheet for my oscilloscope says that the vertical input sensitivity is 1 mV/div to 10 V/div in 1 MΩ mode. But I turn the Vertical Scale control fully clockwise and I can only get down to 10 mV/div. What am I doing wrong?
You probably aren't doing anything wrong. But you do have a 10X probe attached to that channel, right? The 1 mV/div specs relate to the oscilloscope inputs. If the signal’s source impedance is relatively low (<< 1 MOhm), the signal’s frequency is …58571 I have a probe that is no longer being manufactured. What is the replacement?
Please use our "Interactive Probe Selection Tool" to assist in locating a replacement probe for your Tektronix instrument. The interactive tool is located at /node/3661. If your instrument is not located in the upper instrument list, you can click …52846 How can I connect the P6015A High Voltage Probe to oscilloscopes with a 50 Ohm input such as the TDS6000+ TDS7000 and CSA7000 series?
The TCA-1MEG is designed to provide a 1 megohm input to Tektronix oscilloscopes with the TekConnect interface. Bandwidth and input voltage range are well within the the parameters needed for the P6015A. For more information on the TCA-1MEG click …61751